| ECG | Input dynamic range | ±(0.5mVp~5mVp) |
| Differential input impedance | ≥10MΩ | |
| Bandwidth | 0.05~150Hz (Diagnostic) | |
| 0.5~40Hz (Monitoring) | ||
| 1~20Hz (Operation) | ||
| CMRR | ≥90dB (Diagnostic) | |
| ≥105dB (Monitoring & Operation) | ||
| Sensitivity selection | ×1/4, ×1/2, ×1, ×2, ×4 and Auto | |
| Sweeping speed | 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s | |
| HR measuring range | 15~350bpm | |
| HR accuracy | ±1% or ±2bpm, whichever is greater | |
| Pacemaker pulse detection and rejection function | ||
| RESP | Measuring range | 0~120rpm |
| Measuring accuracy | ±5% or ±2 rpm, whichever is greater | |
| TEMP | Measuring range | 21.0~50.0℃ |
| Measuring accuracy | ±0.2℃ from 25~45℃ | |
| NIBP | Technique | Oscillometric method |
| Typical measurement time | <30 seconds (adult cuff) | |
| NIBP measuring range | SYS: 40~275mmHg (Adult) 40~200mmHg (Pediatric) | |
| 40~135mmHg (Neonate) | ||
| NIBP measuring range | DIA: 10~210mmHg (Adult) 10~150mmHg (Pediatric) | |
| 10~95mmHg (Neonate) | ||
| NIBP measuring range | MAP: 20~230mmHg (Adult) 20~165mmHg (Pediatric) | |
| 20~110mmHg (Neonate) | ||
| NIBP measuring accuracy | Mean difference: ±5mmHg | |
| Standard deviation: 8mmHg | ||
| NIBP measurement mode | Manual, Auto, STAT, Multi-cycle mode | |
| Auto measuring intervals | 1-480min | |
| SpO2 | Technique | Dual-wavelength optical method |
| Measuring range | 0%~100% | |
| Measuring accuracy | Arms are not greater than 2% for SpO2 range 70~100%. | |
| PR measuring range | 30~250bpm | |
| PR measuring accuracy | ±2bpm or ±2%, whichever is greater | |
| Low perfusion performance | As low as 0.3%. | |
| CO2 | Technique | Infrared optical method |
| Sampling mode | Sidestream or Mainstream | |
| Measuring range | 0~150mmHg | |
| Measuring accuracy: | 0~40mmHg ±2mmHg | |
| 41~70mmHg ±5% of reading | ||
| 71~100mmHg ±8% of reading | ||
| 101~150mmHg ±10% of reading | ||
| Flow rate | 50ml/min ±10 ml/min (Sidestream) | |
| Cerebral State Monitoring (CSM) | EEG sensitivity | ±400µV |
| Noise level | <2µVp-p, <0.4µV RMS (1~250Hz) | |
| CMRR | >140dB | |
| Input impedance | >50Mohm | |
| CSI and update | 0-100. filter: 6-42Hz, 1 sec. update | |
| EMG% | 0-100 (logarithmic) | |
| filter: 75-85 Hz, 1 sec. update | ||
| BS% | 0-100. filter: 2-42 Hz, 1 sec. update | |
| IBP | Technique | Strain gauge transducer |
| Input sensitivity | 5µV/V/mmHg | |
| Measuring range | -50~300mmHg | |
| Measuring accuracy | ±2% or ±4mmHg, whichever is greater | |
| Measuring positions | ART, RAP, PA, LAP, CVP | |
| ICP, AUXP1, AUXP2 | ||
| Calibration | zero calibrating | |
| Cardiac Output (C.O.) | Blood temperature | 23-43℃, accuracy: ±0.5℃ |
| measuring: range | ||
| Injecta temperature | 0-20℃, accuracy: ±0.5℃ | |
| measuring: range | ||
| Measuring range | 0.2~20 L/min | |
| Measuring accuracy | ±0.2 L/min or ±10%, whichever is greater | |
| Other Specifications | Power supply | AC 100V-240V, 50/60Hz, 60VA |
| Built-in lithium battery | 11.1V/4400mAh | |
| Display | 12.1 inch TFT display | |
| Alarming method | 3 levels audible-visible alarm | |
| Networking | Ethernet | |
| Standard configuration | ECG, Respiration, SpO2, PR, NIBP, Temperature | |
| Option | Touch Screen, 2-IBP, EtCO2, Nellcor SpO2, SunTech NIBP, 12-lead ECG, Cardiac Output, Cerebral | |